Tubes for PLASMOTHERAPY with sodium citrate, 10ml
Vacuum tube 10 ml for plasma therapy with sodium citrate 3.2% and gel. Preserves viability of residual cells, increased volume for treatment of large areas.
Class IIa medical device
Not a laboratory tube. Certified for therapeutic use (ISO 13485). The cost difference compared to laboratory tubes is less than 2% of the procedure price. Why does this matter?
Volume:
10 ml
Purpose:
PPP, plasma therapy
Anticoagulant:
Sodium citrate
Separating gel:
Yes
Medical devices are intended for use by qualified healthcare professionals in accordance with the manufacturer's instructions. The information on the website is for informational purposes only and does not replace medical consultation. More details
Certified. Products have undergone the conformity assessment in accordance with the Technical Regulation on Medical Devices (CMU Resolution No. 753). ISO 13485:2016 quality management system. View certificates
Key advantage: gel + citrate
Combination of separation gel and sodium citrate ensures obtaining maximally clean plasma with preservation of residual cellular elements viability, providing additional therapeutic effect.
Key characteristics
How it works
Unique combination of sodium citrate and separation gel ensures obtaining clean injectable plasma with maximum preservation of its biological properties.
Anticoagulant role
Sodium citrate provides reliable anticoagulation by binding calcium ions (Ca2+) — key cofactor of coagulation cascade. This is "gentle" anticoagulant optimally suited for plasma therapy.
Separation gel role
Separation gel — main technological feature of this tube. This is biologically inert olefin polymer (thixotropic gel), specific gravity of which precisely selected between specific gravity of plasma and blood formed elements.
Material role
Glass tube body made of medical borosilicate glass, providing optimal conditions for preserving blood components.
What you will get
Final product characteristics
Light yellow or straw-colored liquid plasma. Approximately 4–5 ml from 10 ml of blood. Stable for up to 48 hours.
Biological activity
Plasma contains wide range of biologically active components:
Usage time
Recommended to use plasma within 10-30 minutes after obtaining for maximum effectiveness. Thanks to separation gel, sample remains stable significantly longer.
Clinical application
Plasma therapy tube with sodium citrate and separation gel intended for wide range of medical and aesthetic procedures.
Best suited for
Skin biorevitalization and hydration procedures, cases when clean plasma needed without high platelet concentration, complex anti-age programs as basic component, tissue preparation before other procedures.
Why choose this tube
Separation gel
Plasma purity and work convenience guarantee. Gel forms stable barrier between plasma and cellular mass.
Increased plasma yield
Maximum product from each blood draw. Approximately 4-5 ml clean plasma from 10 ml blood.
Sodium citrate
Residual cell viability preservation for additional therapeutic effect.
Larger 10 ml volume
18% more plasma compared to 8.5 ml tubes. More material for large area treatment.
Sample stability
Up to 48 hours without quality change thanks to separation gel.
Versatility
Suitable for wide range of plasma therapy and biorevitalization procedures.
Recommended protocol
Protocol compliance ensures obtaining highest quality plasma with maximum therapeutic potential.
Preparation
Check package integrity and expiration date. Make sure gel located at tube bottom. Prepare necessary equipment: blood collection needle, holder, centrifuge, syringes.
Blood draw
Perform venipuncture using standard technique. Wait for complete tube filling (10 ml). After filling, carefully invert tube 5-6 times to mix with anticoagulant.
Centrifugation
Install tube in centrifuge vertically. Balance rotor (for odd number use water counterweight). Centrifuge at standard speed for 5-10 minutes. After centrifugation gel forms clear barrier between plasma and cells.
Obtaining plasma
Carefully remove tube without tilting or shaking. Gel reliably holds cellular mass — mixing risk minimal. Using syringe with needle, draw plasma above gel barrier. Expected volume: 4-5 ml clean plasma.
Application
Administer plasma within 10-30 minutes after obtaining. Follow injection technique for selected area (papular, linear, bolus).
Important
Important: don't shake too vigorously to avoid foaming gel.
Why do therapeutic tubes cost more than laboratory tubes?
MM Medic tubes are class IIa medical devices certified for therapeutic use. Laboratory tubes (IVD) are intended exclusively for testing and disposal, not for introduction into the human body.
Contents
Safe anticoagulants (citrate, heparinate) or no additives (PRF)—formulated for therapeutic use. Laboratory tubes contain EDTA, which irreversibly destroys platelets.
Material
Medical borosilicate glass or special medical-grade PET—selected for the specific therapeutic protocol. Laboratory tubes are not designed for contact between their contents and the patient's tissues.
Certification
ISO 13485:2016, safety class IIa, gamma sterilization, individual sterile packaging. Laboratory tubes carry only an IVD marking.
Note
The cost difference compared to laboratory tubes is 50–80 UAH—less than 2% of the procedure cost (2,500–5,000 UAH). Using uncertified tubes for injections violates the law and puts the patient's health at risk. Learn more in the FAQ
Important warnings
Single use only. Reuse prohibited.
Reviews
To leave review, log into system or register
No reviews yet
Be first to leave review about this product!